6. Résultats de la modélisation B#

6.1. Valeurs testées#

Identification

Référence

Aster

% différence

tolérance

Température \((°C)\)

Noeud N1 t = 0.1s

0.330

0.330

 0.129

1%

“ “ t = 0.3s

0.544

0.543

 0.149

1%

“ “ t = 0.5s

0.682

0.681

 0.154

1%

“ “ t = 0.7s

0.789

0.788

 0.092

1%

“ “ t = 1.0s

0.918

0.920

0.222

1%

Noeud N8 t = 0.1s

0.330

0.330

 0.129

1%

“ “ t = 0.3s

0.544

0.543

 0.149

1%

“ “ t = 0.5s

0.682

0.681

 0.154

1%

“ “ t = 0.7s

0.789

0.788

 0.092

1%

“ “ t = 1.0s

0.918

0.920

0.222

1%

Noeud N121 t = 0.1s

0.004

0.004

10.931

1%

“ “ t = 0.3s

0.071

0.071

0.242

1%

“ “ t = 0.5s

0.160

0.161

0.587

1%

“ “ t = 0.7s

0.247

0.251

1.619

1%

“ “ t = 1.0s

0.366

0.380

3.95

1%

Noeud N126 t = 0.1s

0.004

0.004

10.931

1%

“ “ t = 0.3s

0.071

0.071

0.242

1%

“ “ t = 0.5s

0.160

0.161

0.587

1%

“ “ t = 0.7s

0.247

0.251

1.619

1%

“ “ t = 1.0s

0.366

0.380

3.95

1%

6.2. Remarques#

L’erreur relative est au maximum de 3.95%, sauf pour \(x=1\) à l’instant \(t=\mathrm{0.1s}\) l’erreur est de 11%. Cette erreur a été obtenue pour la plus petite valeur de la température (\(T=0.004°C\) ). Cet écart s’explique par le fait que la fonction d’erreur en ce point est de 0.025347 et que l’incertitude sur le calcul de la fonction d’erreur est inconnue.