2. Solution de référence#

2.1. Méthode de calcul utilisée pour la solution de référence#

\(T(x,y,t)=\sum_{n=1}^{\infty}\sum_{j=1}^{\infty}{A}_{n}\sin\frac{n\pi x}{{L}_{x}}\sin\frac{j\pi y}{{L}_{y}}\exp\left[-(\frac{{\lambda}_{x}{n}^{2}{\pi}^{2}}{{L}_{x}^{2}}+\frac{{\lambda}_{y}{j}^{2}{\pi}^{2}}{{L}_{y}^{2}})t/\rho c\right]\)

où \({A}_{n}=\left[\frac{4({T}_{i})}{{\pi}^{2}jn}[{(-1)}^{n}-1][{(-1)}^{j}-1]-32\right]\frac{5}{9}\) \({T}_{i}=\frac{5}{9}{T}_{0}+32\)

Température en \(°C\) à \(t=\mathrm{4320s}\)

3.0

-17.7778

-17.5742

-17.3905

-17.2448

-17.1515

-17.1189

2.7

-17.7778

-17.5764

-17.3948

-17.2507

-17.1581

-17.1262

2.4

-17.7778

-17.5832

-17.4077

-17.2684

-17.1790

-17.1482

2.1

-17.7778

-17.5945

-17.4291

-17.2979

-17.2137

-17.1847

1.8

-17.7778

-17.6102

-17.4590

-17.3391

-17.2620

-17.2355

1.5

-17.7778

-17.6302

-17.4970

-17.3914

-17.3235

-17.3002

1.2

-17.7778

-17.6542

-17.5426

-17.4541

-17.3973

-17.3777

0.9

-17.7778

-17.6816

-17.5949

-17.5261

-17.4819

-17.4667

0.6

-17.7778

-17.7120

-17.6526

-17.6056

-17.5753

-17.5649

0.3

-17.7778

-17.7444

-17.7142

-17.6903

-17.6749

-17.6696

0.0

-17.7778

-17.7778

-17.7778

-17.7778

-17.7778

-17.7778

\(Y\uparrow\) \(X\to\)

0.0

0.3

0.6

0.9

1.2

1.5

Les valeurs de référence sont obtenues avec \(n=j=1000\)

2.2. Résultats de référence#

\(t=4\mathrm{320s}(\mathrm{1.2hr})\) : température aux points suivants :

  • en \(x=0.6\) : pour \(y=0.6,1.5,2.4,3.0\)

  • en \(x=1.5\) : pour \(y=0.6,1.5,2.4,3.0\)

2.3. Incertitude sur la solution#

Solution analytique.

2.4. Références bibliographiques#

  1. J.C. Bruch Jr., G. Zyroloski, ‘Transient two-dimensional heat conduction problems solved by the finite element method’, Int. J. num. Meth. Engng, vol 8, n°3, pp 481-494, 1974.